Mărculescu, Afrodita Doina, Leonard Vasile Vasilescu, Corina Paraschiva Ciobanu, Earar Kamel, Cristian Cătalin Gavăt. 2020. “Reducing the determination errors of the international normalized ratio by using plasma cogulation calibrators”. Lucrări Științifice USAMV - Iași Seria Medicină Veterinară 62 (4): 403-406. |
en_US |
dc.identifier.uri |
https://repository.iuls.ro/xmlui/handle/20.500.12811/842 |
|
dc.description.abstract |
The objective was to use of a minimum number of ISI (International Sensitivity Index) to determine the International Normalized Ratio (INR). This specific calibration methods allowed to calculate ISI for all other thromboplastines comparative with the reference thromboplastine. Bigger values than 1 show a decrease sensitivity, as compared with the reference thromboplastine. The Prothrombin Time (PT) values are not the same in all laboratory because of differences in sensitivity of thromboplastins used. To standardize the same results in any laboratory, an INR (International Normalised Ratio) constant has been introduced. Estimation of thromboplastine sensitivity is useful in any laboratory involved in the medical control of therapy with AVK, being also helpull for the clinicians to find out a suitable curative dealing. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
”Ion Ionescu de la Brad” University of Agricultural Sciences and Veterinary Medicine, Iași |
en_US |
dc.rights |
Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) |
|
dc.rights.uri |
https://creativecommons.org/licenses/by/4.0/ |
|
dc.subject |
reference thromboplastin |
en_US |
dc.subject |
ISI |
en_US |
dc.subject |
INR |
en_US |
dc.subject |
plasma calibrants |
en_US |
dc.subject |
oral anticoagulants |
en_US |
dc.title |
Reducing the determination errors of the international normalized ratio by using plasma cogulation calibrators |
en_US |
dc.type |
Article |
en_US |
dc.author.affiliation |
Afrodita Doina Mărculescu, Leonard Vasile Vasilescu, Corina Paraschiva Ciobanu, Cristian Cătalin Gavăt, “Gr. T. Popa” University of Medicine and Pharmacy Iasi, Romania |
|
dc.author.affiliation |
Earar Kamel, “Dunarea de Jos” University of Galati, Romania |
|
dc.publicationName |
Lucrări Științifice USAMV - Iași, Seria Medicină Veterinară |
|
dc.volume |
62 |
|
dc.issue |
4 |
|
dc.publicationDate |
2019 |
|
dc.startingPage |
403 |
|
dc.endingPage |
406 |
|
dc.identifier.eissn |
2393-4603 |
|