Reducing the determination errors of the international normalized ratio by using plasma cogulation calibrators

Show simple item record

dc.contributor.author Mărculescu, Afrodita-Doina
dc.contributor.author Vasilescu, Leonard-Vasile
dc.contributor.author Ciobanu, Corina-Paraschiva
dc.contributor.author Kamel, Earar
dc.contributor.author Gavăt, Cristian-Cătălin
dc.date.accessioned 2021-04-16T08:17:00Z
dc.date.available 2021-04-16T08:17:00Z
dc.date.issued 2019
dc.identifier.citation Mărculescu, Afrodita Doina, Leonard Vasile Vasilescu, Corina Paraschiva Ciobanu, Earar Kamel, Cristian Cătalin Gavăt. 2020. “Reducing the determination errors of the international normalized ratio by using plasma cogulation calibrators”. Lucrări Științifice USAMV - Iași Seria Medicină Veterinară 62 (4): 403-406. en_US
dc.identifier.uri https://repository.iuls.ro/xmlui/handle/20.500.12811/842
dc.description.abstract The objective was to use of a minimum number of ISI (International Sensitivity Index) to determine the International Normalized Ratio (INR). This specific calibration methods allowed to calculate ISI for all other thromboplastines comparative with the reference thromboplastine. Bigger values than 1 show a decrease sensitivity, as compared with the reference thromboplastine. The Prothrombin Time (PT) values are not the same in all laboratory because of differences in sensitivity of thromboplastins used. To standardize the same results in any laboratory, an INR (International Normalised Ratio) constant has been introduced. Estimation of thromboplastine sensitivity is useful in any laboratory involved in the medical control of therapy with AVK, being also helpull for the clinicians to find out a suitable curative dealing. en_US
dc.language.iso en en_US
dc.publisher ”Ion Ionescu de la Brad” University of Agricultural Sciences and Veterinary Medicine, Iași en_US
dc.rights Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject reference thromboplastin en_US
dc.subject ISI en_US
dc.subject INR en_US
dc.subject plasma calibrants en_US
dc.subject oral anticoagulants en_US
dc.title Reducing the determination errors of the international normalized ratio by using plasma cogulation calibrators en_US
dc.type Article en_US
dc.author.affiliation Afrodita Doina Mărculescu, Leonard Vasile Vasilescu, Corina Paraschiva Ciobanu, Cristian Cătalin Gavăt, “Gr. T. Popa” University of Medicine and Pharmacy Iasi, Romania
dc.author.affiliation Earar Kamel, “Dunarea de Jos” University of Galati, Romania
dc.publicationName Lucrări Științifice USAMV - Iași, Seria Medicină Veterinară
dc.volume 62
dc.issue 4
dc.publicationDate 2019
dc.startingPage 403
dc.endingPage 406
dc.identifier.eissn 2393-4603