Assessment of the subcooling capabilities of a thermoelectric device in a vapor compression refrigeration system

Show simple item record

dc.contributor.author Roșca, Radu
dc.contributor.author Țenu, Ioan
dc.contributor.author Cârlescu, P.
dc.contributor.author Rakoși, E.
dc.contributor.author Manolache, Gh.
dc.date.accessioned 2025-01-29T08:50:01Z
dc.date.available 2025-01-29T08:50:01Z
dc.date.issued 2008
dc.identifier.citation Roșca, R., I. Țenu, P. Cârlescu, E. Rakoși, Gh. Manolache. 2008. "Assessment of the subcooling capabilities of a thermoelectric device in a vapor compression refrigeration system". Lucrări Ştiinţifice USAMV - Iaşi Seria Agronomie 51(2): 224-229.
dc.identifier.uri https://repository.iuls.ro/xmlui/handle/20.500.12811/5058
dc.description.abstract The paper presents some theoretical results regarding the subcooling capabilities of a thermoelectric device. The refrigeration system taken into account uses the R-134a refrigerant; a constant refrigerant flow of 1.4 m3/h was considered for all the working variants. The CoolPack refrigeration software was used in order to make the necessary calculations. A TEC 1 12710 type Peltier cooler was considered for subcooling of the liquid refrigerant and its characteristics were evaluated based on experimental tests. The subcooling temperature taken into account was comprised between 0 (no subcooling) and 10K; the cooling capacity, subcooling load and COP were then calculated. The same refrigeration system equipped with a suction gas heat exchanger (SGHX) was considered as reference. The Peltier cooler achieved high COP (5.6…7.7) for low subcooling degrees (1…3K). The overall COP of the refrigeration system with thermoelectric subcooling reached a maximum COP of 2.507 for 5K subcooling and the cooling capacity was comprised between 505 and 557 W. The use of SGHX led to higher overall COP (2.56…2.79); in the meantime, a lower COP and cooling capacity were obtained when no subcooling was applied (COP = 2.45; 0 Q 500 W). en_US
dc.language.iso en en_US
dc.publisher “Ion Ionescu de la Brad” University of Agricultural Sciences and Veterinary Medicine, Iaşi en_US
dc.subject refrigeration system en_US
dc.subject subcooling en_US
dc.subject thermoelectric module en_US
dc.title Assessment of the subcooling capabilities of a thermoelectric device in a vapor compression refrigeration system en_US
dc.type Article en_US
dc.author.affiliation R. Roșca, I. Țenu, P. Cârlescu, University of Agricultural Sciences and Veterinary Medicine, Iaşi
dc.author.affiliation E. Rakoși, Gh. Manolache, Technical University Iaşi
dc.publicationName Lucrări Ştiinţifice USAMV - Iaşi Seria Agronomie