ALSERepository of Iași University of Life Sciences, ROMANIA

The impact of the storage conditions and type of clearomizers on the increase of heavy metal levels in electronic cigarette liquids retailed in Romania

Show simple item record

dc.contributor.author Jităreanu, Alexandra
dc.contributor.author Coroi Cara, Irina-Gabriela
dc.contributor.author Sava, Alexandru
dc.contributor.author Mârțu, Ioana
dc.contributor.author Caba, Ioana-Cezara
dc.contributor.author Agoroaei, Luminița
dc.date.accessioned 2024-06-10T09:50:24Z
dc.date.available 2024-06-10T09:50:24Z
dc.date.issued 2022-03-05
dc.identifier.citation Jităreanu, Alexandra, Irina Gabriela Cara, Alexandru Sava, Ioana Mârțu, Ioana-Cezara Caba, and Luminița Agoroaei. 2022. "The Impact of the Storage Conditions and Type of Clearomizers on the Increase of Heavy Metal Levels in Electronic Cigarette Liquids Retailed in Romania". Toxics 10, no. 3: 126. https://doi.org/10.3390/toxics10030126. en_US
dc.identifier.uri https://repository.iuls.ro/xmlui/handle/20.500.12811/4116
dc.identifier.uri https://www.mdpi.com/2305-6304/10/3/126
dc.description.abstract The growing popularity of electronic cigarettes has raised several public health concerns, including the risks associated with heavy metals exposure via e-liquids and vapors. The purpose of this study was to determine, using atomic absorption spectrometry, the concentrations of Pb, Ni, Zn, and Co in some commercially available e-liquid samples from Romania immediately after purchase and after storage in clearomizers. Lead and zinc were found in all investigated samples before storage. The initial concentrations of Pb ranged from 0.13 to 0.26 mg L􀀀1, while Zn concentrations were between 0.04 and 0.07 mg L􀀀1. Traces of nickel appeared in all investigated e-liquids before storage but in very small amounts (0.01–0.02 mg L􀀀1). Co was below the detection limits. We investigated the influence of the storage period (1, 3, and 5 days), storage temperature (22 C and 40 C), and type of clearomizer. In most cases, the temperature rise and storage period increase were associated with higher concentrations of heavy metals. This confirms that storage conditions can affect metal transfer and suggests that the temperature of storage is another parameter that can influence this phenomenon. en_US
dc.language.iso en en_US
dc.publisher MDPI en_US
dc.rights Attribution 4.0 International (CC BY 4.0)
dc.rights.uri http://creativecommons.org/licenses/by/4.0
dc.subject e-liquids en_US
dc.subject heavy metals en_US
dc.subject storage en_US
dc.subject clearomizers en_US
dc.subject electronic cigarette en_US
dc.title The impact of the storage conditions and type of clearomizers on the increase of heavy metal levels in electronic cigarette liquids retailed in Romania en_US
dc.type Article en_US
dc.author.affiliation Alexandra Jităreanu, Ioana-Cezara Caba, Luminița Agoroaei, Department of Toxicology, Faculty of Pharmacy, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Ias, i, Romania
dc.author.affiliation Irina Gabriela Cara, Research Institute for Agriculture and Environment, “Ion Ionescu de la Brad” University of Life Sciences, 700115 Iasi, Romania
dc.author.affiliation Alexandru Sava, Department of Analytical Chemistry, Faculty of Pharmacy, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Ias, i, Romania
dc.author.affiliation Ioana Mârțu, Department of Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Ias, i, Romania
dc.publicationName Toxics
dc.volume 10
dc.issue 3
dc.publicationDate 2022
dc.startingPage
dc.endingPage
dc.identifier.eissn 2305-6304
dc.identifier.doi 10.3390/toxics10030126


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution 4.0 International (CC BY 4.0) Except where otherwise noted, this item's license is described as Attribution 4.0 International (CC BY 4.0)